Name : SLH103 Solvent-free epoxy coating FJC

FEATURES

PRODUCT NAME SLH103 Solvent-free epoxy coating FJC
BRIEF Two Pack Solvent-free High Build Can be coated Self-curing Coal Pitch Epoxy Coating
FEATURES  
-Excellent physical properties and chemical resistance
-Excellent water resistance, microbiological corrosion resistance and plant root corrosion resistance
-High solid, long life
-Good cure properties of low temperature and cathodic protection
RESISTANCE GUIDE
HEAT RESISTANCE      Up to 120℃ dry heat.
WEATHERABILITY     Gloss reduction and cracking will occur with long-term exterior exposure
SOLVENTS         Resists splash and spillage of most aliphatic hydrocarbon solvents and most common alcohols.
ACIDS          Suitable for splash and spillage to mild acids.
ALKALIS         Suitable for splash and spillage to most common alkalis.
SALTS          Excellent resistance to neutral and alkali salts.
WATER          Excellent resistance to immersion in water.
ABRASION        Good when fully cured.
USES: Widely used in Ship, oil platform, bridge, marine facilities, pipeline, etc.
TYPICAL PROPERTIES AND APPLICATION DATA
COLOUR                    Brown Black/Black
DENSITY                    1.45g/cm3
SOLIDS BY VOLUME               ≥97% (mixture)
SOLIDS BY WEIGHT              98%
SPREADING RATE           13.38 m2/kg  (250um DFT)
DRYING TIME(23℃)   Touch  8 Hr  Handle  24 Hr  Full cure 7Days
OVERCOAT INTERVAL(23℃)      Min 16 Hr  Max 7 Days 
STORAGE               at least 12 months (dry, cool and under cover )
PACKAGING             Part A: 21kg  Part B:3kg
MIXING RATIO (M/M)         Part A : Part B=7:1
MIXING RATIO (V/V)         Part A : Part B=3.3:1 or 2.6:1
CURE TIME(23℃)          none
POT LIFE(23℃)          1 Hr
DIRECTIONS  Before using stir or using dynamic mixer mixing two components completely, Just mix a good raw material and mixing of raw materials before can not be together. Rate of cure will vary depending on temperature and other factors such as ventilation, film thickness, humidity, thinner. The temperature of stir will >15℃, otherwise thinner should be added for needed viscosity after stir.
Overmuch thinner will lead sag and slow cure rate, thin film, thinner should be added after mixed. Practical spreading rates may be reduced 5%—25% for wastage of different application conditions.
APPLICATION  

STEEL: Steel surface must be prepared by abrasive blast cleaning to ISO Standard Class Sa2.5 or power tool cleaning Class St3. The surface coated by shop primer should be dry, clean and no dirt, take the second descaling where film damaged or corrosion, and achieve Sa2.5 level or St3 level. Clear the zinc salt with high pressure fresh water or  sand . Weld and the damage parts processing to Sa2.5 level or St3 level.
Don’t apply at temperatures below 5℃ or above 40℃. Don’t apply at relative humidity above 85% or when the surface is less than 3℃ above the dew point.
Don’t apply if there is fog, rain, snow or strong wind.
BRUSH/ROLLER: Suitable for small areas only. Apply even coats of the mixed material to the prepared surface. Thin if necessary with up to 0-5% with Special Thinner. Additional coats may be required to attain specified thickness.
CONVENTIONAL SPRAY: Thinning is not normally required, however 0-5% of Special Thinner can be added.
AIRLESS SPRAY: Thinning is not normally required, however 0-5% of Special Thinner can be added. Pump ratio is 32:1 or 45:1 and fluid tip is 0.43-0.48 mm.
Overcoating: Aged coating should be tested for lifting by a method such as ‘X’cut or crosshatch methods. If it lifts, remove it. The surface must be free of oil, grease and other contaminants.
Previous coat: Zinc Rich Epoxy Primer, Anticorrosive Epoxy Primer
CLEAN UP: with Epoxy Thinner X-2
SAFETY: Pay attention to the safety precautions before and after using this product. Users should comply with the provision of the respective country or local government. It’s dangerous or deadly to eating it. To avoid inhalation of thinner steams and spray mists.
Use protective wears correctly; the skin and eyes should avoid contacting it. Use with good ventilation. This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT SMOKE. Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.


Please leave your question and we'll get back to you as soon as possible!